FlexContain
PROJECT
Fiscal Host: Helpful
A tool-free isolation room kit: a PVC-lock frame, plastic walls and floor, and a HEPA air unit, sized around one patient bed.
Budget
Transparent and open finances.
Credit from Amish Chadha to FlexContain •
+$20.00USD
Completed
Contribution #982889
$
Today’s balance$17.03 USD
Total raised
$17.03 USD
Total disbursed
--.-- USD
Estimated annual budget
$20.00 USD
About

The problem: In outbreaks and surges, health systems and responders consistently run short of isolation space. Permanent isolation rooms work but are costly and fixed; tents are fast and cheap but only separate droplets and contact. Schools and other buildings turned into treatment wards usually have no isolation at all.
What we're building: A room that stores flat and assembles on site, to supplement permanent isolation rooms, not replace them. We're also exploring a doorway insert with a viewing panel, glove-box access and ports for air and power.
How it works: Aluminum or PVC tubing joins with tool-free PVC-lock fittings and carries polyethylene or vinyl walls and floor, with a magnet-closed flap door. An off-the-shelf HEPA unit in a modified tote with an inline fan cleans the air, with at least 12 air changes an hour required. Targets: two people assemble it in under 60 minutes, and the floor holds 600 lb and a standard bed.
Why it matters now: A field isolation unit available today costs around $18,000. Our target is about $1,500 per system, a fraction of that.
Where it's needed: Overflow wards, temporary and rural clinics, and buildings repurposed as treatment wards.
Partners: Helpful Engineering.
Project team: Amish Chadha, Lillian Fernandes, Raksha Thammaiah, Michael Min and Ali Raza.
Where it stands: TRL 2, concept formulated. Requirements are drafted with many values still open, and we dropped a first aluminum-and-rigid-panel design as too costly. No prototype exists, and it is not a certified medical device; we plan to publish it open source with test data and disclaimers. Renders are concept studies, and the readiness level is self-assessed.
What your gift does: Around $2,000 covers the materials for one full room, frame to air unit, so we can build it and time the 60-minute setup target. Gifts go first to parts and materials, then to bench testing and the shipping in between.
100% to this project. Every dollar given here goes to FlexContain's budget, and you can see every expense on this page. Every donor is credited on every design Helpful releases. Helpful Engineering is a registered 501(c)(3) (EIN 85-0673635), and gifts are tax-deductible in the US to the extent the law allows.
Our team
Today's Balance
$17.03
Estimated Annual Budget
$20
First prototype room
$2,000
Contribute
Become a financial contributor.
Financial Contributions
Custom contribution
Your $5
The gift we're asking of everyone who has joined Helpful. If every one of you gives $5, at least two of our designs reach TRL 5, tested in a settin... Read more
Starts at
$5 USD
One-time contribution
Pay for a prototype round
One build-and-test round of FlexContain: parts, circuit boards, sensors, materials and the shipping to move them. It decides whether the design is ... Read more
$1,000 USD
One-time contribution
Present the research
Takes FlexContain's results to a conference: the travel and logistics to present them, registration fees, and the writing, editing and submission c... Read more
$700 USD
FlexContain is all of us
Our contributors 1